M510T
pH
● 1-8 points calibration with Standard Recognition.
● Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.
Model
|
M510T
|
|
Parameters
|
pH/EC/ISE/DO/Temp (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)
|
|
pH |
Range
|
-2.000 to 20.000 pH
|
Resolution
|
0.1, 0.01, 0.001pH
|
|
Accuracy
|
±0.002 pH
|
|
Calibration Points
|
Up to 8
|
|
Standard Customization
|
Yes
|
|
Calibration Reminder
|
Yes
|
|
Standard Recognition
|
USA, NIST, MERK, JIS, GB and DIN buffers
|
|
Slope Limit
|
Yes
|
|
mV/ORP
|
Range
|
-2000.00 to 2000.00 mV
|
Resolution
|
0.1, 0.01 mV
|
|
Accuracy
|
±0.1 mV or ±0.03%
|
|
EH ORP Mode
|
Yes
|
|
ORP Calibration Points
|
1 custom point (relative mV)
|
|
pX |
Range
|
-2.000 to 20.000 pX
|
Resolution
|
0.1, 0.01, 0.001 pX
|
|
Accuracy
|
±0.002 pX
|
|
Calibration Points
|
Up to 6
|
|
ISE
|
Range
|
1.000e-9 to 9.999e+9
|
Units
|
mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
|
|
Resolution
|
Up to 4 significant digits
|
|
Accuracy
|
±0.3%
|
|
Calibration Points
|
Up to 8
|
|
Conductivity
|
Range
|
0.000 μS/cm to 3000 mS/cm
|
Resolution
|
0.001 μS/cm minimum, various with range selection
|
|
Accuracy
|
±0.5% FS
|
|
Reference Temperature
|
5, 10, 15, 18, 20, 25 ºC
|
|
Reference Temperature
|
Up to 5
|
|
Calibration Reminder
|
Yes
|
|
Standard Recognition
|
10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm; 146.5μS/cm,
1408μS/cm, 12.85mS/cm, 111.3mS/cm
|
|
Resistivity
|
Range
|
5.00 Ω·cm~100.0 MΩ·cm
|
Resolution
|
0.01 Ω·cm minimum
|
|
Accuracy
|
±0.5% FS
|
|
TDS
|
Range
|
0.000 ppm~1000 ppt
|
Resolution
|
0.001ppm minimum, changed with range
|
|
Accuracy
|
±0.5% FS
|
|
Salinity
|
Range
|
0.0 ~ 80.0 ppt
|
Resolution
|
0.1ppt
|
|
Accuracy
|
±1ppt
|
|
Dissolved
Oxygen Concentra-
tion
|
Sensor Type
|
Polarographic
|
Range
|
0.00 to 99.99 ppm
|
|
Resolution
|
0.01 ppm
|
|
Accuracy
|
±0.10ppm, 0.00~50.00ppm
±0.50ppm, 50.0~99.99ppm
|
|
Calibration Reminder
|
Yes
|
|
Calibration Points
|
Air-saturated water or zero point
|
|
Barometric Compensation
|
Yes | |
Manual Salinity Factor Correction
|
Yes
|
|
Saturation
|
Range
|
(0.0 to 600.0)%
|
Resolution
|
0.10%
|
|
Accuracy
|
±2.0%
|
|
Temperature
|
Range
|
-10 to 135 ºC, 14 to 275 ºF
|
Unit
|
ºC, ºF
|
|
Resolution
|
0.1
|
|
Relative Accuracy
|
±0.1
|
|
Measurement
|
Reading Mode
|
Auto Read (Fast, Medium, Slow), Timed, Continuous
|
Reading Prompts
|
Reading, Stable, Locked
|
|
Temp. Compensation
|
ATC, MTC
|
|
Data management
|
Data Storage
|
1000 Groups
|
GLP Features
|
Yes
|
|
Inputs
|
pH Electrode
|
BNC(Q9)
|
DO with Temp. Probe
|
4-pin aviation connector
|
|
Conductivity with Temp. Probe
|
5-pin aviation connector
|
|
Outputs
|
USB
|
USB 2.0 flash memory device, PC, scanner
|
Display options
|
Backlight
|
Yes
|
Auto Shutdown
|
300, 600, 1200, 1800, 3600 sec., off
|
|
IP Rating
|
IP65
|
|
Date and Time
|
Yes | |
General
|
Power
|
Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output
|
Dimensions
|
90×255×40 mm
|
|
Weight
|
500g (1.1 lb)
|